-- CISCO-ATM-NETWORK-CLOCK-MIB.my:  CISCO-ATM-NETWORK-CLOCK MIB file
--   
-- Dec 1998, David Kushi
--   
-- Copyright (c) 1998-1999, 2008 by Cisco Systems Inc.
-- All rights reserved.
-- *****************************************************************
--   
-- *****************************************************************
-- $Endlog

CISCO-ATM-NETWORK-CLOCK-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    NOTIFICATION-TYPE,
    Integer32
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION,
    TruthValue,
    TimeStamp,
    RowStatus
        FROM SNMPv2-TC
    ciscoMgmt
        FROM CISCO-SMI
    entPhysicalIndex,
    PhysicalIndex
        FROM ENTITY-MIB
    MODULE-COMPLIANCE,
    OBJECT-GROUP,
    NOTIFICATION-GROUP
        FROM SNMPv2-CONF;


ciscoAtmNetworkClockMIB MODULE-IDENTITY
    LAST-UPDATED    "200802180000Z"
    ORGANIZATION    "Cisco System Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: 170 West Tasman Drive,
            San Jose CA 95134-1706.
            USA

            Tel: +1 800 553-NETS

            E-mail: cs-atm@cisco.com"
    DESCRIPTION
        "The MIB module for management of network clock        distribution
        and the Network Clock Distribution Protocol (NCDP) in Cisco 
        devices.

        In the context of this MIB 'network clock' refers to the
        clock signal that is used to time the physical interfaces.
        Network clock distribution refers to the distribution of a
        clock signal through a device and between devices for use
        by the physical interfaces.  (See Bell Communications 
        Research, GR-1244-CORE, 'Clocks for the Synchronized
        Network: Common  Generic Criteria' and Bell Communications
        Research, GR-436-CORE, 'Digital Network Synchronization 
        Plan').

        NCDP is used to configure the network clocking hardware of 
        the platform on which an NCDP entity exists.  The underlying
        network clocking hardware in turn distributes a clock signal
        through the device for use by the physical interfaces.  When
        all of the interfaces that support synchronous clock 
        recovery in a network are timed to one master clock signal,
        the network is said to be synchronized.

         NCDP protocol entities residing on adjacent devices 
        cooperate through the exchange of protocol messages to
         construct a spanning network clock distribution tree.
        The tree preserves the synchronous digital hierarchy.

        After NCDP has determined that its algorithm has converged
        it superimposes the clock distribution tree on the
        underlying network and the result is a synchronized
        network."
    REVISION        "200802180000Z"
    DESCRIPTION
        "The SYNTAX of following objects changed from INTEGER to Integer32.
         cncNcdpMessageInterval, cncNcdpHoldTime ,cncNcdpPriority ,
         CncNcdpAtmEntry ,cncNcdpAdminWeight,cncNcdpVpi,
         cncNcdpVci ."
    REVISION         "200112110000Z"
    DESCRIPTION 
         "Intial MIB version."
    ::= { ciscoMgmt 121 }


-- CISCO-ATM-NETWORK-CLOCK MIB groups

ciscoAtmNetworkClockMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIB 1 }

cncGlobal  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIBObjects 1 }

cncManualSource  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIBObjects 2 }

cncNcdpSource  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIBObjects 3 }

cncNcdp  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIBObjects 4 }


-- textual conventions

CncStratum ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The stratum level associated with a source of network clock
        or a device.  (See American National Standards Institute,
        ANSI T1.101, 'Synchronization Interface for Digital 
        Networks' and Bell Communications Research, GR-436-CORE,
        'Digital Network Synchronization Plan' for more detailed
        information.)"
    SYNTAX          INTEGER  {
                        s1(1),
                        s2e(2),
                        s2(3),
                        s3e(4),
                        s3(5),
                        s4e(6),
                        s4(7),
                        other(8)
                    }

CncHealth ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The health of a source of network clock.

        A value of 'good' indicates that a given source of network 
        clock is known by the managed system to be good.

        A value of 'bad' indicates that a given source of network 
        clock is known by the managed system to be bad.

        A value of 'unknown' indicates that the health of the 
        source of network clock is unknown to the managed system."
    SYNTAX          INTEGER  {
                        good(1),
                        bad(2),
                        unknown(3)
                    }

-- scalars

cncDistributionMethod OBJECT-TYPE
    SYNTAX          INTEGER  {
                        ncdp(1),
                        manual(2)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The method used to distribute network clock for the device.
        When the mode of operation is 'ncdp', the services provided
        by the NCDP entity are in use.  When this is the case, NCDP
        entities residing on adjacent nodes exchange protocol 
        messages that are used by the resident NCDP entity to select
        clock source such that a network-wide clock distribution 
        tree is constructed.  When the mode of operation is manual,
        the NCDP entity is not in use and sources of network clock
        are statically configured.  When this is the case, the
        construction of a network-wide clock distribution tree is 
        done manually by a network administrator or NMS 
        application."
    DEFVAL          { manual } 
    ::= { cncGlobal 1 }

cncNotificationOnChange OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The value of this object determines whether a notification
        should be generated due to a change in the device's root 
        clock source (given by the value of cncRootClockSource).  
        A value of 'true' enables the generation of notifications;
        'false' disables notification generation."
    DEFVAL          { true } 
    ::= { cncGlobal 2 }

cncNodeStratum OBJECT-TYPE
    SYNTAX          CncStratum
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The stratum at which the device exists in the Synchronous
        Digital Hierarchy (See American National Standards 
        Institute, ANSI T1.101, 'Synchronization Interface for
        Digital Networks' and Bell Communications Research,
        GR-436-CORE, 'Digital Network Synchronization Plan' for 
        more detailed information regarding stratum.).

        The resident NCDP entity uses the value of this object to
        enforce the network clock distribution stratum hierarchy.

        This object is only used by the NCDP protocol entity." 
    ::= { cncGlobal 3 }

cncNcdpMaxDiameter OBJECT-TYPE
    SYNTAX          Integer32 (3..255 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The maximum possible height of a network clock distribution
        tree in the network.  (Alternatively this is known as the 
        maximum diameter of the network of devices that are 
        participating in NCDP.)  If all of the nodes in the network 
        are participating in the protocol then the maximum height of
        the network clock distribution tree is exactly the maximum
        diameter of the network.  If a proper subset of the nodes
        are participating in the NCDP then the maximum height of a
        network clock distribution tree is the maximum diameter of 
        the subnetwork induced by the removal of the 
        non-participating nodes and their associated links.

        The NCDP protocol entity uses the value of this object to
        determine when the NCDP algorithm has converged.  All 
        devices participating in NCDP within the bounds of the
        network must use the same value for maximum network diameter
        for the NCDP algorithm to operate properly. If the value of
        this object is set too small the resultant network may 
        exhibit unstable clocking characteristics and may constantly
        switch clock sources.  If the value is much larger than the
        network diameter, the algorithm will take longer to declare
        convergence than if the diameter were set closer to the 
        actual maximum network diameter, the result being that it 
        will take longer for the network to resynchronize after a 
        switchover to a secondary clock source located on a
        secondary device.

        This object is only used by the NCDP protocol entity." 
    ::= { cncGlobal 4 }

cncNcdpMessageInterval OBJECT-TYPE
    SYNTAX          Integer32 (75..60000 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The interval at which NCDP configuration PDUs are to be
        generated.

        The message interval directly affects the convergence time 
        of the NCDP algorithm.  Convergence time is equal to the max 
        network diameter * message interval + transmission delays + 
        the time a configuration PDU is spent being processed in  
        each device.  Thus if transmission delays and processing 
        delays are  both close to 0, the convergence time is
        approximately ( max network diameter * message interval )
        milliseconds.

        The value of cncNcdpHoldTime should normally match the value 
        of this object.

        This object is only used by the NCDP protocol entity."
    DEFVAL          { 500 } 
    ::= { cncGlobal 5 }

cncNcdpHoldTime OBJECT-TYPE
    SYNTAX          Integer32 (75..60000 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The delay between the transmission of NCDP configuration
        PDUs.

        The hold time is used to limit the transmission of NCDP 
        configuration PDUs out of an interface to a maximum of one
        configuration PDU per hold time interval per interface.

        The value of this object should normally be set        to match the 
        value of cncNcdpMessageInterval.  If the value of this 
        object is higher than the value of cncNcdpMessageInterval,
        NCDP configuration PDUs will end up being propagated at
        the rate specified by the value of this object instead.

        This object is only used by the NCDP protocol entity."
    DEFVAL          { 500 } 
    ::= { cncGlobal 6 }

cncSourceChangeReason OBJECT-TYPE
    SYNTAX          INTEGER  {
                        none(1),
                        lossOfLock(2),
                        lossOfActivity(3),
                        ncdpRestructure(4),
                        other(5)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The reason for the most recent change of a source of
        network clock, as indicated by the change in the value 
        of cncSourceChangeTimeStamp.

        'none' indicates that the source of network clock 
        has not changed.

        'lossOfLock' indicates that the clock source was 
        changed because the network clocking hardware lost 
        lock on the previous network clock source.

        'lossOfActivity' indicates that the clock source was changed
        because the network clocking hardware detected a loss of 
        activity on the previous network clock source.

        'ncdpRestructure' indicates that the NCDP entity has changed 
        the clock source as a result of a network-wide network clock 
        distribution tree restructuring process.

        When the reason for a clock switchover is none of the 
        above, the value of this object is 'other'." 
    ::= { cncGlobal 7 }

cncSourceChangeTimeStamp OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The value of sysUpTime when the most recent change of a
        source of network clock occurred.

        A value of 0 indicates that no such event has occurred since 
        the instantiation of this object."
    DEFVAL          { 0 } 
    ::= { cncGlobal 8 }

cncRootClockSource OBJECT-TYPE
    SYNTAX          PhysicalIndex
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The entPhysicalIndex of the network clock source that is
        actively supplying network clock within the device." 
    ::= { cncGlobal 9 }
-- table of objects representing static network clock sources

cncManualSourceTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CncManualSourceEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A table of network clock sources available to the managed
        system."
    ::= { cncManualSource 1 }

cncManualSourceEntry OBJECT-TYPE
    SYNTAX          CncManualSourceEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Network clock status and statistics for sources of network
        clock.  When the value of cncDistributionMethod is 'manual',
        the managed system uses this table to select a source of 
        network clock for the managed system.  Within this table a
        physical entity that is a source of network clock is 
        identified by cncManualSourceId.  Table entries are indexed 
        by priority (cncManualSourcePriority).

        A source of network clock for the device may be an 
        oscillator local to the device, a Building Integrated
        Timing Supply (BITS) port or an interface that supports
        synchronous clock  recovery. (BITS is explained in more
        detail in Bell Communications Research, GR-436-CORE,
        'Digital Network Synchronization Plan'.)

        When the managed system initializes it creates a row for 
        the device's default source of network clock, (the entry
        having cncManualSourcePriority with value 'default').  The
        only operations allowed on the columnar objects in this
        particular row are read operations.

        Other rows are created or destroyed by a management station
        or through the device's local management interface when a 
        source of network clock is configured or removed.  When a
        management station creates a row it creates it explicitly 
        using RowStatus with either createAndGo or createAndWait.
        A row is not made active until a valid value for
        cncManualSourceId is supplied.  A management station may
        perform a write operation on any columnar object while the
        row is active or not in service.

        The value of any instance of cncManualSourceId located in
        the table is unique except when the value refers to the 
        device's default source of network clock; any instance of
        cncManualSourceId within the table may have this value at
        any time."
    INDEX           { cncManualSourcePriority } 
    ::= { cncManualSourceTable 1 }

CncManualSourceEntry ::= SEQUENCE {
        cncManualSourcePriority INTEGER ,
        cncManualSourceId       PhysicalIndex,
        cncManualSourceHealth   CncHealth,
        cncManualRowStatus      RowStatus
}

cncManualSourcePriority OBJECT-TYPE
    SYNTAX          INTEGER  {
                        primary(1),
                        secondary(2),
                        default(3)
                    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A value used to identify a source of network clock
        available to the device's manual network clock selection
        algorithm." 
    ::= { cncManualSourceEntry 1 }

cncManualSourceId OBJECT-TYPE
    SYNTAX          PhysicalIndex
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The entPhysicalIndex that uniquely identifies a source of
        network        clock within the managed system." 
    ::= { cncManualSourceEntry 2 }

cncManualSourceHealth OBJECT-TYPE
    SYNTAX          CncHealth
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The health of the clock source identified by
        cncManualSourceId." 
    ::= { cncManualSourceEntry 3 }

cncManualRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The status of this conceptual row." 
    ::= { cncManualSourceEntry 4 }
 

-- table of objects representing network clock sources advertised by
-- ncdp

cncNcdpSourceTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CncNcdpSourceEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A table of configured network clock sources available to
        the managed system for use by the NCDP protocol entity."
    ::= { cncNcdpSource 1 }

cncNcdpSourceEntry OBJECT-TYPE
    SYNTAX          CncNcdpSourceEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Network clock status and statistics for sources of network
        clock identified by entPhysicalIndex and used by the managed
        system when the value of cncDistributionMethod is 'ncdp'.

        A source of network clock for the device may be an
        oscillator local to the device, a Building Integrated Timing
        Supply (BITS) port or an interface that supports synchronous
        clock recovery.
        (BITS is explained in more detail in Bell Communications
        Research, GR-436-CORE, 'Digital Network Synchronization 
        Plan'.)

        The NCDP protocol entity selects one entry in this table to
        advertise as the best available clock source for the device.
        Cooperating NCDP protocol entities select the best available
        clock source among those advertised within the cooperating
        group and build a clock        distribution tree rooted at that 
        clock source.  When the value of cncRootClockSource is used
        as an index into this table and the indicated clock source
        has cncNcdpBestClockSource with value 'true' then the
        indicated clock source is the root of some clock
        distribution tree.  If only one such root exists on all 
        participating devices in the network, then it is the root of
        a network wide clock distribution tree.

        When the managed system initializes it creates a row for the
        device's default source of network clock.  This row cannot be
        destroyed by a management station.  Within this row a write
        operation is only allowed on the cncNcdpPriority object; only
        read operations are allowed on all other columnar objects
        within this specific row.  The status of this row is always
        active.  The default source can always be found by issuing a
        read operation on the row within cncManualSourceTable indexed
        by 'default' (as the value of cncManualSourcePriority).  The
        cncManualSourceId object contains the entPhysicalIndex of the
        default source of network clock and identifies it within this
        table.

        Other rows are created or destroyed by a management station
        or through the device's local management interface when a 
        source of network clock is configured or removed.  When a
        management station creates a row it creates it explicitly  
        using RowStatus with either createAndGo or createAndWait. 
        A row is not made active until all read-create objects not 
        having default values are properly initialized.

        The values of cncNcdpPriority, cncNcdpStratum and
        cncNcdpPRSReference collectively describe a source of network
        clock, that is they are three components of a vector used as 
        an input to the NCDP algorithm to make clock source selection
        decisions.  The management station must make the row 
        notInService before changing the values of any of these 
        objects."
    INDEX           { entPhysicalIndex } 
    ::= { cncNcdpSourceTable 1 }

CncNcdpSourceEntry ::= SEQUENCE {
        cncNcdpBestClockSource TruthValue,
        cncNcdpPriority        Integer32,
        cncNcdpStratum         CncStratum,
        cncNcdpPRSReference    INTEGER ,
        cncNcdpSourceHealth    CncHealth,
        cncNcdpRowStatus       RowStatus
}

cncNcdpBestClockSource OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "An indication of whether the NCDP entity is presently
        advertising this clock source as the best clock source 
        available in this table." 
    ::= { cncNcdpSourceEntry 1 }

cncNcdpPriority OBJECT-TYPE
    SYNTAX          Integer32 (1..255 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The network-wide priority of this clock source if
        configured as a source of network clock for NCDP. The
        highest priority clock source is that clock source having 
        the lowest positive numeric value.  The clock source with
        the highest priority is selected as the root of the clock
        distribution tree by the NCDP algorithm.  If more that one
        clock source is configured with with the same priority the 
        NCDP algorithm uses the value cncNcdpStratum as a
        tiebreaker."
    DEFVAL          { 128 } 
    ::= { cncNcdpSourceEntry 2 }

cncNcdpStratum OBJECT-TYPE
    SYNTAX          CncStratum
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The stratum level associated with this clock source if
        configured as a source of network clock for NCDP.  (See 
        American National Standards Institute, ANSI T1.101, 
        'Synchronization Interface for Digital Networks' and Bell 
        Communications Research, GR-436-CORE, 'Digital Network
        Synchronization Plan' for more detailed information 
        regarding stratum.).  If the value of this object is used
        as a tiebreaker  by the NCDP protocol entity, the lower of
        the given values is the winner.  If the values are the
        same, the value of cncNcdpPRSReference is used as a
        tiebreaker by the NCDP algorithm." 
    ::= { cncNcdpSourceEntry 3 }

cncNcdpPRSReference OBJECT-TYPE
    SYNTAX          INTEGER  {
                        internal(1),
                        external(2)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "An value that identifies the primary reference source that
        the network clock available from this source is traceable 
        to if configured as a source of network clock for NCDP.
        (See American National Standards Institute, ANSI T1.101,
        'Synchronization Interface for Digital Networks' and Bell 
        Communications Research, GR-436-CORE, 'Digital Network 
        Synchronization Plan' for more        detailed information 
        regarding Primary Reference Sources.).  If a source of 
        network clock is an onboard oscillator local to the device
        it is 'internal' otherwise it is 'external'.  If the value
        of this object is used as a tiebreaker by the NCDP
        algorithm,'external' wins over 'internal'.

        All 'external' sources of network clock are assumed to be
        traceable to the same PRS by the NCDP protocol entity." 
    ::= { cncNcdpSourceEntry 4 }

cncNcdpSourceHealth OBJECT-TYPE
    SYNTAX          CncHealth
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The health of the clock source associated with this row." 
    ::= { cncNcdpSourceEntry 5 }

cncNcdpRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The status of this conceptual row." 
    ::= { cncNcdpSourceEntry 6 }
 

-- table of objects used to support ncdp protocol entity at atm
-- interfaces

cncNcdpAtmTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CncNcdpAtmEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A table containing the status of NCDP on the device's ATM
        interfaces."
    ::= { cncNcdp 1 }

cncNcdpAtmEntry OBJECT-TYPE
    SYNTAX          CncNcdpAtmEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry in the cncNcdpAtm table containing the status of
        Ncdp on an ATM interface.

        A row in this table is created by the managed system and
        disappears when the associated physical entity disappears.

        When a row is created all of the row objects are 
        instantiated."
    INDEX           { entPhysicalIndex } 
    ::= { cncNcdpAtmTable 1 }

CncNcdpAtmEntry ::= SEQUENCE {
        cncNcdpEnable      TruthValue,
        cncNcdpAdminWeight Integer32,
        cncNcdpVpi         Integer32,
        cncNcdpVci         Integer32,
        cncNcdpHealth      CncHealth
}

cncNcdpEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "An indication of whether NCDP is presently running on an
        interface.  When NCDP is enabled for an interface, the
        interface is an active member of the clock distribution
        topology as seen by the NCDP protocol entity.

        After this object is instantiated by the agent the
        managed system initializes the value of this object to 'true'
        if it determines that the physical interface is an ATM
        Network-to-Network Interface (see ATM Forum Private
        Network-Network Interface Specification        Version 1.0).  In 
        all other cases the managed system initializes the value of
        this object to 'false'." 
    ::= { cncNcdpAtmEntry 1 }

cncNcdpAdminWeight OBJECT-TYPE
    SYNTAX          Integer32 (1..16777215 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "A weight metric used by the NCDP protocol entity and
        associated with a physical interface that supports 
        synchronous clock recovery.  When NCDP is enabled for the
        physical interface the value of this object is used by NCDP
        algorithms during tree computations.

        The lower the administrative weight, the more attractive 
        the given link is to the NCDP algorithm.  If the weight of
        a link is changed, it can cause the NCDP protocol entity
        to reconstruct the clock distribution tree."
    DEFVAL          { 10 } 
    ::= { cncNcdpAtmEntry 2 }

cncNcdpVpi OBJECT-TYPE
    SYNTAX          Integer32 (0..4095 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The VPI value of the VCC supporting the NCDP entity at this
        ATM interface.  If the values of cncNcdpVpi and
        cncNcdpVci are both equal to zero then the NCDP entity 
        is not supported at this ATM interface."
    DEFVAL          { 0 } 
    ::= { cncNcdpAtmEntry 3 }

cncNcdpVci OBJECT-TYPE
    SYNTAX          Integer32 (0..65535 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The VCI value of the VCC supporting the NCDP entity at this
        ATM interface.  If the values of cncNcdpVpi and
        cncNcdpVci are both equal to zero then the NCDP entity 
        is not supported at this ATM interface."
    DEFVAL          { 34 } 
    ::= { cncNcdpAtmEntry 4 }

cncNcdpHealth OBJECT-TYPE
    SYNTAX          CncHealth
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The health of the clock source associated with this row." 
    ::= { cncNcdpAtmEntry 5 }
 

-- notifications

ciscoAtmNetworkClockNotificationPrefix  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIB 2 }

ciscoAtmNetworkClockMIBNotifications  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockNotificationPrefix 0 }


cncNotifySourceChange NOTIFICATION-TYPE
    OBJECTS         { cncSourceChangeReason }
    STATUS          current
    DESCRIPTION
        "This notification indicates that the agent has detected a
        change in the device's root source of network clock.  This 
        notification is generated whenever there is a switchover
        from one clock source to another."
   ::= { ciscoAtmNetworkClockMIBNotifications 1 }
-- conformance information

ciscoAtmNetworkClockConformance  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockMIB 3 }

ciscoAtmNetworkClockMIBCompliances  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockConformance 1 }

ciscoAtmNetworkClockMIBGroups  OBJECT IDENTIFIER
    ::= { ciscoAtmNetworkClockConformance 2 }


-- compliance statements

cncMIBCompliance MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "The compliance statement for SNMPv2 entities which
        implement network clock distribution methods and NCDP."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cncGroup,
                        cncNotificationGroup
                    }
    ::= { ciscoAtmNetworkClockMIBCompliances 1 }

-- units of conformance

cncGroup OBJECT-GROUP
    OBJECTS         {
                        cncDistributionMethod,
                        cncNotificationOnChange,
                        cncNodeStratum,
                        cncNcdpMaxDiameter,
                        cncNcdpMessageInterval,
                        cncNcdpHoldTime,
                        cncSourceChangeReason,
                        cncSourceChangeTimeStamp,
                        cncRootClockSource,
                        cncManualSourceId,
                        cncManualSourceHealth,
                        cncManualRowStatus,
                        cncNcdpBestClockSource,
                        cncNcdpPriority,
                        cncNcdpStratum,
                        cncNcdpPRSReference,
                        cncNcdpSourceHealth,
                        cncNcdpRowStatus,
                        cncNcdpEnable,
                        cncNcdpAdminWeight,
                        cncNcdpVpi,
                        cncNcdpVci,
                        cncNcdpHealth
                    }
    STATUS          current
    DESCRIPTION
        "The cnc group of objects providing for management of
        network clock distribution and NCDP entities."
    ::= { ciscoAtmNetworkClockMIBGroups 1 }

cncNotificationGroup NOTIFICATION-GROUP
   NOTIFICATIONS    { cncNotifySourceChange }
    STATUS          current
    DESCRIPTION
        "Conformance group for cnc notifications."
    ::= { ciscoAtmNetworkClockMIBGroups 2 }

END